H3C Technologies H3C S3100V2 Series Switches User Manual
Page 57
51
Item S3100V2-26TP-EI
S3100V2-16TP-EI
S3100V2-8TP-EI
Relative humidity
(noncondensing)
10% to 90%
Fire resistance
compliance
UL60950-1, EN60950-1, IEC60950-1, GB4943
Chassis leakage
current compliance
UL60950-1, EN60950-1, IEC60950-1, GB4943
S3100V2-TP-PWR-EI switches technical specifications
Table 15 S3100V2-TP-PWR-EI switches technical specifications
Item S3100V2-26TP-PWR-EI
S3100V2-16TP-PWR-EI
S3100V2-8TP-PWR-EI
Dimensions (H × W ×
D)
43.6 × 440 × 420 mm
(1.72 × 17.32 × 16.54 in)
43.6 × 440 × 420 mm
(1.72 × 17.32 × 16.54 in)
43.6 × 300 × 220 mm
(1.72 × 11.81 × 8.66 in)
Weight
≤ 6.5 kg (14.33 lb)
≤ 6 kg (13.23 lb)
≤ 3 kg (6.61 lb)
24 10/100Base-TX
auto-sensing Ethernet ports
2 combo interfaces
(numbered 25 and 26)
16 10/100Base-TX
auto-sensing Ethernet ports
2 combo interfaces
(numbered 17 and 18)
8 10/100Base-TX
auto-sensing Ethernet
ports
1 combo interface
(numbered 9)
Fixed ports
NOTE:
Each combo interface has one 100/1000Base-X fiber SFP port and one
10/100/1000Base-T auto-sensing copper Ethernet port. These two ports share one port
name and port view and cannot work simultaneously. When you activate one port (by
using the combo enable { copper | fiber } command), the other port automatically shuts
down.
Management ports
1 console port
AC-input
•
Rated voltage: 100 VAC to 240 VAC, 50 or 60 Hz
•
Max voltage: 90 VAC to 264 VAC, 47 Hz to 63 Hz
Input
voltage
DC-input
•
Rated voltage: –47 VDC to –57 VDC
•
Max voltage: –47 VDC to –-57 VDC
NOTE:
You can connect the switch chassis to a –48 VDC power
source or an H3C external RPS. For the RPSs available for
the switches and their specifications, see the
RPS Ordering
Guide for H3C Low-End Series Ethernet Switches
and their
respective user manuals.
N/A
Input current
AC: 8 A
DC: 19.5 A
AC: 6 A
DC: 12 A
2 A
Melting current of
power supply fuse
AC: 10 A
DC: 25A
AC: 10 A
DC: 25A
5 A
Max output
power/PoE port
15.4 W
15.4 W
15.4 W
PoE ports
24
16
8