Safety with laser, Examining the installation site, Temperature requirements – H3C Technologies H3C S3100V2 Series Switches User Manual
Page 15: Humidity requirements
9
Figure 14 Use an ESD-preventive wrist strap
1
(1) Rack post
Safety with laser
The S3100V2 Switch Series is a line of class 1 laser products. When a transceiver module on an
S3100V2 switch is operating, do not stare into the optical port because the laser light emitted from the
optical fiber may hurt your eyes.
Examining the installation site
The S3100V2 Switch Series must be used indoors. To ensure normal operation and long service life of
your switch, install it in an environment that meets the requirements described in the following
subsections.
Temperature requirements
To ensure the normal operation of the switch, make sure that the room temperature meets the
requirements described in
Table 2 Temperature requirements
Temperature Range
Operating temperature
0°C to 45°C (32°F to 113°F)
Storage temperature
–40°C to +70°C (–40°F to +158°F)
CAUTION:
If condensation appears on the switch when you move it to a high-temperature environment, dry the switch
before powering it on to avoid short circuits.
Humidity requirements
Maintain appropriate humidity in your equipment room, as described in