H3C Technologies H3C S12500-X Series Switches User Manual
Page 88
81
IP Packet Frame Type:PKTFMT_ETHNT_2, Hardware Address: 0011-2200-0102
IPv6 Packet Frame Type:PKTFMT_ETHNT_2, Hardware Address: 0011-2200-0102
Physical: Unknown, baudrate: 1000000 kbps
Last clearing of counters: Never
Last 300 seconds input rate: 0 bytes/sec, 0 bits/sec, 0 packets/sec
Last 300 seconds output rate: 0 bytes/sec, 0 bits/sec, 0 packets/sec
Input: 0 packets, 0 bytes, 0 drops
Output: 0 packets, 0 bytes, 0 drops
# Verify that the VXLAN tunnels have been assigned to VXLAN 10, and VSI-interface 1 is the
gateway interface for the VSI vpna.
[SwitchB] display l2vpn vsi name vpna verbose
VSI Name: vpna
VSI Index : 0
VSI State : Up
MTU : 1500
Bandwidth : -
Broadcast Restrain : -
Multicast Restrain : -
Unknown Unicast Restrain: -
MAC Learning : Enabled
MAC Table Limit : -
Drop Unknown : -
Flooding : Enabled
Gateway interface : VSI-interface 1
VXLAN ID : 10
Tunnels:
Tunnel Name Link ID State Type
Tunnel1 0x5000001 Up Manual
# Verify that Switch B has created ARP entries for the VMs.
[SwitchB] display arp
Type: S-Static D-Dynamic O-Openflow M-Multiport I-Invalid
IP address MAC address VLAN Interface Aging Type
12.1.1.4 0000-fc00-00ab N/A Vlan12 14 D
25.1.1.5 4431-9234-24bb N/A Vlan20 17 D
10.1.1.1 0000-fc00-00ab N/A Vsi1 17 D
10.1.1.11 0000-fc00-00ab N/A Vsi1 20 D
20.1.1.1 0000-fc00-00aa N/A Vsi3 17 D
20.1.1.12 0000-fc00-00aa N/A Vsi3 20 D
# Verify that Switch B has created FIB entries for the VMs.
[SwitchB] display fib 10.1.1.11
Destination count: 1 FIB entry count: 1
Flag:
U:Useable G:Gateway H:Host B:Blackhole D:Dynamic S:Static
R:Relay F:FRR
Destination/Mask Nexthop Flag OutInterface/Token Label
10.1.1.11/32 10.1.1.11 UH Vsi1 Null
[SwitchB] display fib 20.1.1.12
Destination count: 1 FIB entry count: 1