beautypg.com

Configuring vxlan is-is, Vxlan is-is configuration task list, Specifying a reserved vxlan for vxlan is-is – H3C Technologies H3C S12500-X Series Switches User Manual

Page 51

background image

44

Configuring VXLAN IS-IS

Use VXLAN IS-IS to automate VXLAN tunnel assignment and MAC reachability information

synchronization between VTEPs.

VXLAN IS-IS configuration task list

Tasks at a glance

(Required.)

Specifying a reserved VXLAN for VXLAN IS-IS

(Required.)

Enabling VXLAN autonegotiation to automate VXLAN tunnel assignment

(Required.)

Enabling MAC advertisement through VXLAN IS-IS

(Optional.)

Tuning VXLAN IS-IS parameters

Specifying a reserved VXLAN for VXLAN IS-IS

For the VTEP to exchange VXLAN IS-IS packets with remote VTEPs, you must specify a reserved VXLAN.
The reserved VXLAN must be the same across the VTEPs.
You can specify only one reserved VXLAN on the VTEP. All VSIs on the VTEP use the reserved VXLAN to

transmit and receive VXLAN IS-IS packets. The reserved VXLAN cannot be a VXLAN created on any VSI.
To specify a reserved VXLAN for VXLAN IS-IS:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Specify a VXLAN as the
reserved VXLAN.

reserved vxlan vxlan-id

By default, no VXLAN is specified as the
reserved VXLAN.

Enabling VXLAN autonegotiation to automate

VXLAN tunnel assignment

VXLAN autonegotiation enables the VTEPs to advertise local VXLAN IDs through VXLAN IS-IS. Two VTEPs

automatically assign the VXLAN tunnel between them to a VXLAN if both of them have the VXLAN ID.
To automate VXLAN tunnel assignment:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

This manual is related to the following products: