Configuring vxlan is-is, Vxlan is-is configuration task list, Specifying a reserved vxlan for vxlan is-is – H3C Technologies H3C S12500-X Series Switches User Manual
Page 51
44
Configuring VXLAN IS-IS
Use VXLAN IS-IS to automate VXLAN tunnel assignment and MAC reachability information
synchronization between VTEPs.
VXLAN IS-IS configuration task list
Tasks at a glance
Specifying a reserved VXLAN for VXLAN IS-IS
Enabling VXLAN autonegotiation to automate VXLAN tunnel assignment
Enabling MAC advertisement through VXLAN IS-IS
(Optional.)
Specifying a reserved VXLAN for VXLAN IS-IS
For the VTEP to exchange VXLAN IS-IS packets with remote VTEPs, you must specify a reserved VXLAN.
The reserved VXLAN must be the same across the VTEPs.
You can specify only one reserved VXLAN on the VTEP. All VSIs on the VTEP use the reserved VXLAN to
transmit and receive VXLAN IS-IS packets. The reserved VXLAN cannot be a VXLAN created on any VSI.
To specify a reserved VXLAN for VXLAN IS-IS:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Specify a VXLAN as the
reserved VXLAN.
reserved vxlan vxlan-id
By default, no VXLAN is specified as the
reserved VXLAN.
Enabling VXLAN autonegotiation to automate
VXLAN tunnel assignment
VXLAN autonegotiation enables the VTEPs to advertise local VXLAN IDs through VXLAN IS-IS. Two VTEPs
automatically assign the VXLAN tunnel between them to a VXLAN if both of them have the VXLAN ID.
To automate VXLAN tunnel assignment:
Step Command
Remarks
1.
Enter system view.
system-view
N/A