beautypg.com

Troubleshooting, No generator a or generator b led indication, Cannot control module – Ensemble Designs 9400 3G Test Signal and Sync Pulse Generator User Manual

Page 67: Module controls are grayed out, No signal out of module, Troubleshooting 67

background image

www.ensembledesigns.com

Avenue 7400 and 9400 - Page 67

Model 7400 HD/SD and Model 9400 3G/HD/SD Sync Pulse Generator and Test Signal Generator

Troubleshooting

As a troubleshooting aid, the reference signal status and presence, power and CPU status can be easily

monitored from the front panel of this module using the front panel indicators.

Refer to the overall troubleshooting tips given below for Models 7400 and 9400:

No Generator A or Generator B LED indication

• Generator is not locked to its timing source. At least one of the Generator A

or Generator B LEDs should be lit to indicate the primary output line standard

and that it is locked to its timing source. Check source settings in the Global,

SPG A and SPG B menus.

Cannot control module

• Check status of CPU Run green LED. Should be blinking slowly and in unison

with other modules if System Control module is present. If not, try removing

the 7400 or 9400 module and plugging it in again to be sure it is seated

properly.

• System module may not be working properly if installed.

Module controls are grayed out

• Module is locked or access to module controls is restricted by the User Level

which is set in Avenue PC.

No signal out of module

• Check status of Ref green LEDs. One should be lit to indicate which reference

rate is currently being detected. If not, check the reference input or master

frame signal for presence and quality.

• Check cabling to input of module.

You may also refer to the technical support section of the Ensemble Designs web site for the latest

information on your equipment at the URL below:

http://www.ensembledesigns.com/support

This manual is related to the following products: