Timing B Menu
Setting the Timing for Generator B
The Timing B menu shown below allows you to set the timing of the Generator B outputs with
respect to the reference selected in the SPG B menu. This menu affects the SDI output, the principal
output of the generator, which applies to SDI Out B and Programmable Output 1 B (Out 1 B BNC).
Use the slider controls or arrows to select a value or enter a value into the number fields.
• Vert Timing – Set the vertical timing in lines. Range is -525 to 525, default is 0.
• Hor Timing – Set the horizontal timing in clocks. Range is -1716 to 1716, default is 0.
• Fine Phase – Set the fine phase of the Primary output in nanoseconds. Range is -35 to 35,
default is 0.
Timing B Touch Screen Menu
Timing B Avenue PC Menu