beautypg.com

Timing b menu – Ensemble Designs 9400 3G Test Signal and Sync Pulse Generator User Manual

Page 49

background image

www.ensembledesigns.com

Avenue 7400 and 9400 - Page 49

Model 7400 HD/SD and Model 9400 3G/HD/SD Sync Pulse Generator and Test Signal Generator

Timing B Menu
Setting the Timing for Generator B

The Timing B menu shown below allows you to set the timing of the Generator B outputs with

respect to the reference selected in the SPG B menu. This menu affects the SDI output, the principal

output of the generator, which applies to SDI Out B and Programmable Output 1 B (Out 1 B BNC).

Use the slider controls or arrows to select a value or enter a value into the number fields.

• Vert Timing – Set the vertical timing in lines. Range is -525 to 525, default is 0.

• Hor Timing – Set the horizontal timing in clocks. Range is -1716 to 1716, default is 0.

• Fine Phase – Set the fine phase of the Primary output in nanoseconds. Range is -35 to 35,

default is 0.

Timing B Touch Screen Menu

Timing B Avenue PC Menu