beautypg.com

Programmable output 1 a menu – Ensemble Designs 9400 3G Test Signal and Sync Pulse Generator User Manual

Page 33

background image

www.ensembledesigns.com

Avenue 7400 and 9400 - Page 33

Model 7400 HD/SD and Model 9400 3G/HD/SD Sync Pulse Generator and Test Signal Generator

Programmable Output 1 A Menu
Setting the Output, Tri-Level Sync Output Standard, Fine Phase, Vertical Timing and

Horizontal Timing for Programmable Output 1 A

The Pgm 1 A menu shown below allows you to set the Programmable Output 1 A, the Tri-Level Sync

output standard, fine phase, vertical and horizontal timing. This menu affects the Out 1 A BNC.

Note: The selections you make from the Pgm 1 OutSel and TLS Gen 1 Std drop-down menus have to

be from the same frame rate family as the standard selected in the SPG A menu.

Use the controls to set the following:

• Pgm 1 OutSel – Choose from:

Black

Color Bars

Follow SDI Out

TLS Gen 1

When “Follow SDI Out” is selected, the settings from the TSG A menu are being used.

• TLS Gen 1 Std – Choose an output standard from the following options:

720p/50

720p/59.94

720p/60

1080i/50

1080i/59.94

1080i/60

1080p/25

1080p/23.98

1080p/24

1080sF/25

1080sF/23.98

1080sF/24

Use the slider controls or arrows to select a value or enter a value into the number fields.

• Fine Phase – Set the fine phase of the output in nanoseconds. Range is -35 to 35, default is 0.

• Vert Timing – Set the vertical timing in lines. Range is -1000 to 1000, default is 0.

• Hor Timing – Set the horizontal timing in clocks. Range is -2000 to 2000, default is 0.

Note: If you select “Follow SDI Out” from the Pgm 1 OutSel drop-down menu, the Fine Phase,

Vert Timing and Hor Timing controls will be grayed out and will not be usable.