Programmable output 1 a menu – Ensemble Designs 9400 3G Test Signal and Sync Pulse Generator User Manual
Page 33

www.ensembledesigns.com
Avenue 7400 and 9400 - Page 33
Model 7400 HD/SD and Model 9400 3G/HD/SD Sync Pulse Generator and Test Signal Generator
Programmable Output 1 A Menu
Setting the Output, Tri-Level Sync Output Standard, Fine Phase, Vertical Timing and
Horizontal Timing for Programmable Output 1 A
The Pgm 1 A menu shown below allows you to set the Programmable Output 1 A, the Tri-Level Sync
output standard, fine phase, vertical and horizontal timing. This menu affects the Out 1 A BNC.
Note: The selections you make from the Pgm 1 OutSel and TLS Gen 1 Std drop-down menus have to
be from the same frame rate family as the standard selected in the SPG A menu.
Use the controls to set the following:
• Pgm 1 OutSel – Choose from:
Black
Color Bars
Follow SDI Out
TLS Gen 1
When “Follow SDI Out” is selected, the settings from the TSG A menu are being used.
• TLS Gen 1 Std – Choose an output standard from the following options:
720p/50
720p/59.94
720p/60
1080i/50
1080i/59.94
1080i/60
1080p/25
1080p/23.98
1080p/24
1080sF/25
1080sF/23.98
1080sF/24
Use the slider controls or arrows to select a value or enter a value into the number fields.
• Fine Phase – Set the fine phase of the output in nanoseconds. Range is -35 to 35, default is 0.
• Vert Timing – Set the vertical timing in lines. Range is -1000 to 1000, default is 0.
• Hor Timing – Set the horizontal timing in clocks. Range is -2000 to 2000, default is 0.
Note: If you select “Follow SDI Out” from the Pgm 1 OutSel drop-down menu, the Fine Phase,
Vert Timing and Hor Timing controls will be grayed out and will not be usable.