Global menu – Ensemble Designs 9400 3G Test Signal and Sync Pulse Generator User Manual
Page 61
www.ensembledesigns.com
Avenue 7400 and 9400 - Page 61
Model 7400 HD/SD and Model 9400 3G/HD/SD Sync Pulse Generator and Test Signal Generator
Global Menu
Setting Global Parameters for Module Reference and Audio Reference Levels
The parameters set in the Global menu affect the entire 7400 or 9400 module. These settings can be
applied to Generator A and Generator B.
The Global menu shown below allows you to set the parameters for Configuration Reference, Vertical
Interval Time Code, Digital Audio Reference Level, Analog Audio Tone Output and Composite Setup.
Use the controls to set the following:
• Config Ref – Select the desired module reference from the External Reference (525, 625,
Tri-Level Sync or 10 MHz sine wave) or Master Reference (Frame Reference). The presence of
the reference will be reported in the adjacent Reference window.
• Ref VITC Line – Specify the line on which you want to put the Vertical Interval Time Code.
Available selections are: Line 12, Line 13, Line 14, Line 15, Line 16, Line 17, Line 18, Line 19.
• Reference – Reports what reference input is present from the following list:
No Ref, Ref 525, Ref 525 w/VITC, Ref 625, Ref 625 w/VITC, Ref TLS 720p60 (reports this for 59.94
and 60), Ref TLS 720p50, Ref TLS 1080i60 (reports this for 59.94 and 60), Ref TLS 1080i50 (also
reports this for 1080p 25 and 1080sF 25), Ref TLS 1080i24 (reports this for 1080p 23.98 or 24
and 1080sF 23.98 or 24), Ref 10MHz.
• Dig Ref Level – Digital Audio Reference Level. Applies to AES digital. -20dBFS or -18dBFS.
• Anlg Ref Level – Set the Analog Reference Level.
Available selections are: -10dB, -6dB, -4dB, 0dB, +4dB.
• Cpst Setup – Turns Composite Setup On or Off for 525/60 Hz outputs. For most 60 Hz
applications, this option is typically enabled.