Aqua Lung WTX-D Buoyancy System User Manual
Page 10

Table of Contents
© 2014 Apeks
Elliptical Corrugated Hose
The Apeks technical airway found on each buoyancy cell includes a corrugated hose that has an elliptical
cross section. This allows for a lower profile, which reduces drag and lays cleanly over the shoulder. A
retainer loop comes installed on the elliptical hose to streamline the braided MP hose.
Safety Cable in the Airway
A safety cable can be found inside the corrugated hose of each Apeks technical airway. This safety
cable protects the corrugated hose from hyper-extension and tearing that can be caused by any undue
stresses such as snags.
Heavy Duty Inflator Brass Buttons
Technical diving equipment must be robust and reliable. Apeks’ new technical inflator exceeds the
challenge. The secret to its reliability is its simplicity. Fewer parts mean less to go wrong and ease of
service. Once you hold the precision marine brass buttons in your hand, you will quickly realize that this
is not a recreational inflator, but rather a serious tool to meet the dive at hand.
Loops for Optional Retractor Kit
The outer bag has loops sewn to the inside for an optional retractor kit. The retractors will assist in
keeping the buoyancy cell streamlined while diving. The retractor kit may be ordered separately from
your Authorized Apeks Dealer. Instructions for attachment are included with the retractor kit.
Braided MP Inflator Hose
The Apeks technical airway comes equipped with a light weight, braided MP inflator hose. This gives
the airway greater flexibility for inflation / deflation of the buoyancy cell compared to standard MP inflator
hoses that can be cumbersome and difficult to maneuver.
Mesh Drain and Grommets
A mesh drain and grommets will prevent water from pooling in the bottom of the buoyancy cell.
Flat Valve / Dump Valve / Over Pressure Relief (OPR) Valve
Each buoyancy cell comes with a flat valve / dump valve located on the left rear inside of the outer bag.
This easy-to-reach dump valve is convenient for releasing air while inverted and is more streamlined
when compared to a standard dump valve. The over pressure relief (OPR) valve feature allows excess
air to vent from the valve when the bladder is full, preventing damage to the buoyancy cell.
NOTE:
WTX-D18 buoyancy cell does not have loops sewn to the inside of the outer bag,
therefore cannot accommodate the retractor kit.