Westermo MRD-3x0 User Manual
Page 164
164
6623-3201
As shown in Figure 120, the following options can be set for
the Raw TCP Client/Server:
Network type
The Raw TCP serial server can be configured for three differ-
ent network modes:
Accept
The serial server will listen for TCP connections on
the specified port number.
Connect
The serial server will establish a TCP connection to
the specified address and port number.
Accept and Connect
The serial server will normally listen for TCP connec-
tions on the specified port number, however, if data is
received at the serial port and no connection exists, it
will attempt to establish a connection to the specified
address and port number.
Connect address
For Connect or Accept and Connect network modes, this is the
address the server will attempt to connect to. The address
entered should be in IPv4 decimal dotted notation.
Connect port
For Connect or Accept and Connect network modes, this is the
TCP port number the server will attempt to connect to. The
value entered should be a valid TCP port number.
Timeout after failed connect
For Connect or Accept and Connect network modes, if a con-
nection request has failed, the server will wait the amount
of time (in seconds) specified in this field before attempting
another connection request. While a short timeout may cause
the connection to be established more quickly, it may also
cause greater network traffic if the remote host is unavailable
and repeated attempts fail.