46

16.2 Contact operating mode

To enter contact mode press the MODE key, move the selection bar to Contact, and

press SELECT.

The contact mode home screen will be displayed. The home screen displays the

contact dose, the flowrate, and the dose time remaining when a dose is in progress.

The dose time is only displayed on screen when it is between 3 seconds and 999

seconds.

When the pump is not dosing it is possible to manually start a dose by pressing the

START key.

Dose’s which operate for less than 3 seconds are not recommended.

Pulse dosing as an operation mode has its limitations. From an application perspective

it is often not the most efficient method of achieving concentration consistency due

to the pump only metering when a pulse is received, as opposed to continuously

running in proportion to the flow. Intermittently dosing into a fluid line will require

enough pipe to ensure the solution is adequately mixed, or a mixing tank.

With the ability to operate at very low speeds, metering chemicals is a much better

solution than dosing them at intervals. We recommend examining your process to

identify whether a 4-20mA signal can be used rather than a pulse. Where technology

does not allow a 4-20mA signal we recommend a using signal converter accessory.

This can be used to change your pulse signal to a 4-20mA signal, ideal for metering

(see 15.5 Analog 4-20mA mode on page 37).