Users Manual

MC100

MC100 DeviceNet OM 1.15 EN

Version: 1.04

Page 31 of 43

Instance ID

15

Packed parameters from Instance ID 1-7

Read

Attribute ID

Description

Type

Value

1

Name

Byte-String

“Packed Parameters”

2

Data-type

-

double integer

3

Elements

-

6

4

Access

-

Read/Write

5

Data values

Double Integers

Last Write values

6

Max. values

Double Integers

Max. values

17

7

Min. values

Double Integers

Min. values

17

8

Default values

Double Integers

Default values

Write

5

Data values

Double Integers

>= Min and <= max values


Data structure for Instance 15:

Double Integer

1

Volume

2

Tube

3

Speed

4

Acceleration

5

Reverse

6

Density


Instance

16

Tube table – diameters

Read

Attribute ID

Description

Type

Value

1

Name

Byte-String

“Tube Sizes”

2

Data-type

-

Double Integer

3

Elements

-

5

4

Access

-

Read Only

5

Data value

Double integer

See. Table below

6

N.A.

Integer

7

N.A.

Integer

8

N.A.

Integer


Data structure for Instance 16:

Double Integer

1

Tube 1

2

Tube 2

3

Tube 3

4

Tube 4

5

Tube 5

6

Tube 6

7

Tube 7

8

Tube 8

9

Tube 9

10

Tube 10


The values in the table are the inner diameter of the tube multiplied by 10.
Example Tube 3 = 32, equals an inner diameter of 3.2 mm.
NB! Tube diameter = 0 denotes no tube in that entry.