beautypg.com

Users manual, Mc100 – Watson-Marlow MC100 User Manual

Page 25

background image

Users Manual

MC100

MC100 DeviceNet OM 1.15 EN

Version: 1.04

Page 25 of 43

7.2.2 List of additional ADI’s

ADI No.

Description

Data type

Range

Default

8

Packed data ADI 1-6

Double integer

6 elements

See ADI

9

Versions

Char

Max.39 chars

See ADI

Alarm texts strings

See 8.2.1

Warning text strings

See 8.2.2

10

Alarm number

Integer

0-17

0 - See 8.2.1

11

Warning number

Integer

0-9

0 - See 8.2.2

12

Versions / Builds

Integer

-

See ADI

13

Tubes sizes

Integer

10 elements

80

14

Tubes steps/ml

Integer

10 elements

127

15

Packed data ADI 1-6

Double integer

6 elements

See ADI

16

Tubes sizes

Double integer

10 elements

80

17

Tubes steps/ml

Double integer

10 elements

127

18

Misc. Status bits

Integer

1 element

Not described

19

Misc. Diagnostics

Integer

8 elements

Not described

20

Reserved for Balance

Float

1 element

-

21

Reserved for Balance

Double integer

1 element

-

22

Reserved for Balance

Float

1 element

-

23

Reserved for Balance

Integer

1 element

-

24

Reserved for Balance

Integer

1 element

-

25

Packed status

Misc

14 elements

-

26

Distance in steps for
active pump

Double integer

1 element


Common for all these ADI’s are, that they are not necessary for the parameterization of the pumps,
but it is recommended, that at least ADI 9 or ADI 10/11 and ADI 13 is implemented.

ADI 18 and 19 is only used by technicians for service purposes

ADI 8, 15 and ADI 13, 16 and ADI 14, 17 are equal except for the data types, where ADI15,16,17 are
available to make things more easy in Allan Bradley PLC’s.