beautypg.com

Users manual, Mc100 – Watson-Marlow MC100 User Manual

Page 27

background image

Users Manual

MC100

MC100 DeviceNet OM 1.15 EN

Version: 1.04

Page 27 of 43

Instance

4

Acceleration

Read

Attribute ID

Description

Type

Value

1

Name

Byte-String

“Acceleration”

2

Data-type

-

Integer

3

Elements

-

1

4

Access

-

Read/Write

5

Data value

Integer

Last Write value

6

Max. value

Integer

200 (tube dependant)

7

Min. value

Integer

1

8

Default value

Integer

10

Write

5

Data value

Integer

>= Min and <= max value

Instance

5

Reverse

Read

Attribute ID

Description

Type

Value

1

Name

Byte-String

“Reverse”

2

Data-type

-

double integer

3

Elements

-

1

4

Access

-

Read/Write

5

Data value

Double Integer

Last Write value

6

Max. value

Double Integer

10

7

Min. value

Double Integer

0

8

Default value

Double Integer

0

Write

5

Data value

Double Integer

>= Min and <= max value

Instance

6

Density

Read

Attribute ID

Description

Type

Value

1

Name

Byte-String

“ Density”

2

Data-type

-

double integer

3

Elements

-

1

4

Access

-

Read/Write

5

Data value

Double Integer

Last Write value

6

Max. value

Double Integer

2,00000

7

Min. value

Double Integer

0,50000

8

Default value

Double Integer

1000000

Write

5

Data value

Double Integer

>= Min and <= max value

Instance

7

Calibration

Read

Attribute ID

Description

Type

Value

1

Name

Byte-String

“Calibration”

2

Data-type

-

double integer

3

Elements

-

1

4

Access

-

Read/Write

5

Data value

Double Integer

Last Write value

6

Max. value

Double Integer

2 * the value In instance 1

7

Min. value

Double Integer

0,5 * the value In instance 1

8

Default value

Double Integer

Value from instance 1

(no calibration done)

Write

5

Data value

Double Integer

>= Min and <= max value