background image

Users Manual

MC100

MC100 DeviceNet OM 1.15 EN

Version: 1.04

Page 12 of 43

4 Wiring

MC100 Frontplate

1 0

3

4

9

6

8

5

7

2

1 0

3

4

9

6

8

5

7

2

Con 4

Connectors / Indicators / Switches

COMM

BUSY

Con 3

Con 2

Con 1

1

1

2

2

3

X10

X1

Address

Con1

Flexnet

Connector

Connect with

1

/DATA

I/O

PHOENIX

MC 0,5/ 3 –G-2,5THT

PHOENIX

FK MC 0,5/ 3 –ST 2,5

2

GND

-

3

DATA

I/O

The Flexnet connector should be connected to the corresponding terminals on all the pumps,
establishing a multidrop network and the last pump should be terminated with a 120 ohm
resistor between DATA and /DATA.

Use 0.25 – 0.35 mm2 wires twisted or screened. Terminal tubes must be minimum 8 mm long.

Con2

Power Supply

Connector

Connect with

1

+24V

IN

PHOENIX

MC 0,5/ 4 –G-2,5THT

PHOENIX

FK MC 0,5/ 3 –ST 2,5

2

0V

IN

Use 0.5 mm2 wires, terminal tubes must be minimum 8 mm long.