beautypg.com

Users manual, Mc100 – Watson-Marlow MC100 User Manual

Page 29

background image

Users Manual

MC100

MC100 DeviceNet OM 1.15 EN

Version: 1.04

Page 29 of 43

Instance

11

Warning number

Read

Attribute ID

Description

Type

Value

1

Name

Byte-String

“Warning number”

2

Data-type

-

Integer

3

Elements

-

1

4

Access

-

Read Only

5

Data value

Integer

Warning number

6

6

N.A.

Integer

7

N.A.

Integer

8

N.A.

Integer


Instance

12

Firmware Version

Read

Attribute ID

Description

Type

Value

1

Name

Byte-String

“Firmware Version”

2

Data-type

-

Integer

3

Elements

-

1

4

Access

-

Read Only

5

Data value

Integer

MC100 Firmware version

6

Data value

Integer

MC100 Firmware build no.

7

Data value

Integer

Pump HW and SW

8

N.A.

Integer


The data value for attribute 5 is 4 BCD digits

3 (MSB)

2

1

0 (LSB)

Version(x10)

Version(x1)

Major

Minor


Example Version 1, revision 3.7

0

1

3

7


The data value for attribute 6 is build number [integer]

The data value for attribute 7 is 2 bytes

3 (MSB)

2

1

0 (LSB)

TBD

TBD

Pump software

Pump hardware


Pump hardware: BCD1, BCD0.
Pump software: Version = byte/10.

6

Warning – number is a reference to the Warning list The text-string can also be read from Instance 9, Attribute

8. The