Users manual, Mc100 – Watson-Marlow MC100 User Manual
Page 29

Users Manual
MC100
MC100 DeviceNet OM 1.15 EN
Version: 1.04
Page 29 of 43
Instance
11
Warning number
Read
Attribute ID
Description
Type
Value
1
Name
Byte-String
“Warning number”
2
Data-type
-
Integer
3
Elements
-
1
4
Access
-
Read Only
5
Data value
Integer
Warning number
6
6
N.A.
Integer
7
N.A.
Integer
8
N.A.
Integer
Instance
12
Firmware Version
Read
Attribute ID
Description
Type
Value
1
Name
Byte-String
“Firmware Version”
2
Data-type
-
Integer
3
Elements
-
1
4
Access
-
Read Only
5
Data value
Integer
MC100 Firmware version
6
Data value
Integer
MC100 Firmware build no.
7
Data value
Integer
Pump HW and SW
8
N.A.
Integer
The data value for attribute 5 is 4 BCD digits
3 (MSB)
2
1
0 (LSB)
Version(x10)
Version(x1)
Major
Minor
Example Version 1, revision 3.7
0
1
3
7
The data value for attribute 6 is build number [integer]
The data value for attribute 7 is 2 bytes
3 (MSB)
2
1
0 (LSB)
TBD
TBD
Pump software
Pump hardware
Pump hardware: BCD1, BCD0.
Pump software: Version = byte/10.
6
Warning – number is a reference to the Warning list The text-string can also be read from Instance 9, Attribute
8. The
number is also flashing on the 2-digit display [ER][number]