Users manual, Mc100 – Watson-Marlow MC100 User Manual
Page 28

Users Manual
MC100
MC100 DeviceNet OM 1.15 EN
Version: 1.04
Page 28 of 43
Instance ID
8
Packed parameters from Instance ID 1-7
Read
Attribute ID
Description
Type
Value
1
Name
Byte-String
“Packed Parameters”
2
Data-type
-
double integer
3
Elements
-
6
4
Access
-
Read/Write
5
Data values
Double Integers
Last Write values
6
Max. values
Double Integers
Max. values
7
Min. values
Double Integers
Min. values
8
Default values
Double Integers
Default values
Write
5
Data values
Double Integers
>= Min and <= max values
Data structure for Instance 8:
Double Integer
1
Volume
2
Tube
Speed
3
Acceleration
Reverse
4
Density
5
Reserved
6
Reserved
Reserved
Instance
9
Versions- and Alarm strings
Read
Attribute ID
Description
Type
Value
1
Name
Byte-String
“Versions / Alarms / Warnings”
2
Data-type
-
4 (char)
String of (1-39) (char)
3
Elements
-
39
4
Access
-
Read Only
5
MC100 Version
char
MC100 Version
6
Pump version
Char
Pump version
7
Alarm Type
Char
Alarm-string (Read at alarm)
8
Warning Type
char
Warning-string (Read at warning)
Instance
10
Alarm number
Read
Attribute ID
Description
Type
Value
1
Name
Byte-String
“Alarm number”
2
Data-type
-
Integer
3
Elements
-
1
4
Access
-
Read Only
5
Data value
Integer
Alarm number
5
6
N.A.
Integer
7
N.A.
Integer
8
N.A.
Integer
5
Alarm – number is a reference to the Alarm list (Chapter 8).The text-string can also be read from Instance 9, Attribute
7.The number is also flashing on the 2-digit display [AL][number]