Initial installation – Enviro Haven Direct Vent Fireplace User Manual
Page 16

Initial Installation
QUALIFIED INSTALLERS ONLY
Drywall
Plywood
Brick
Drywall
Plywood
Tile
Drywall
Plywood
Figure 21. Bottom Mounting Holes.6
Bottom
Mounting
Holes
Shut-off
Valve
Figure 22. Drywall Facing Only Around The
Haven.
Any of the four (4) different haven faces will allow
for up to a 1” (25mm) thick finishing wall (example
drywall and tile); see Figure 22 & 23. The wall
may be finished up to the fireplace standoffs with
combustible materials. This facing style should tuck
under the at the bottom of the front to conceal the
top of the facing and the bottom of the Haven.
When finishing with brick, the brick must frame
around the outside of the face (see Figure 24).
See the corresponding fascia instruction sheet for
approximate dimensions.
Figure 23. Drywall & Tile Facing Around The
Haven.
Figure 24. Drywall & Brick Facing Around The
Haven.
W
ALL
F
INISHES
:
16