Initial installation, Qualified installers only i, 2 cm height 31 – Enviro Haven Direct Vent Fireplace User Manual
Page 13: 5 cm side gas/electrical inlet: distance back 4
Initial Installation
QUALIFIED INSTALLERS ONLY
I
NTRODUCTION
:
This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement,
hearths, facing, mantles, and venting terminations will be covered, as well as the gas and electric
systems. There are several installation safety guidelines that must be adhered to. Please carefully read
the safety precautions at the front of this manual.
Warning: Clearances must be sufficient to allow access for maintenance and service.
P
LACEMENT
AND
F
RAMING
:
A firestop
is required
through the
rear wall.
18
31
/
32
"
(482mm)
10
3
/
4
"
(273mm)
50" (1.27m)
minimum
Ceiling Height
31
11
/
16
"
(805mm)
3
1
/
2
" min
(89mm)
Ceiling
Sidewall
Figure 14. Dimensions for Framing the Firebox.
13
27
11
/
32
"
(695mm)
We recommend
installing these
frame pieces
after the unit
is installed.
10
13
/
32
"
(264mm)
4
9
/
32
"
(102mm)
4
11
/
32
"
(110mm)
Table 2. Framing Dimensions.
Firebox Framing
Depth
103⁄4”
27.3 cm
Width
18
31
/
32
”
48.2 cm
Height
31
11
/
16
”
80.5 cm
Side Gas/Electrical Inlet:
Distance back
4
3
/
16
”
10.6 cm
Distance up
15⁄8”
4.1 cm
Bottom Gas/Electrical Inlet:
Distance back
3
13
/
16
”
9.7 cm
Distance up
13⁄4”
4.4 cm
Figure 15. Dimensions for Top
Framing the Firebox.
The fireplace can be located along a wall, raised or at floor level, or in
a corner. There are specific framing measurements for each situation.
The basic opening should have the dimensions shown in Figure 4.
Refer to Figure 1 for the placement of the gas and electrical inlets.
When the basic framing is done and the unit is installed the three (3)
top pieces of the framing should be installed Figure 15.
The fireplace must have a strong and level surface to be placed on. The surface should be made of wood
or a non-combustible material, not carpet.