Initial Installation
QUALIFIED INSTALLERS ONLY
The framing boards may touch the top, side and back standoffs, but no insulation or other material
can be placed between the frame and the standoffs.
The gas line, 3⁄8 inch NPT, can be brought to either the right side, the left side, or the bottom of
the fireplace. If this set up is inconvenient, the electrical wire and the gas line configuration can be
reversed.
The location should be chosen so the fireplace must be at least 36 inches (91.4 cm) from drapes, doors
and other combustibles. The framed opening should also be a minimum of 3.5 inches (8.9 cm) from the
nearest perpendicular wall (sidewall to the edge of the opening).
The HAVEN is designed so it can be installed at floor level without a required hearth
.
C
ORNER
I
NSTALLATION
:
R
AISED
F
IREPLACES
AND
H
EARTHS
:
Even though the Haven can be installed at floor level without a hearth, there are a few options with raised
fireplaces: raised with a floor level hearth (Figure 17), raised with a raised hearth (Figure 18), or raised
with no hearth (Figure 19). If the fireplace is raised, it cannot be placed within 18 inches (45.7cm) of the
ceiling. When installing a raised fireplace, it is imperative that the support stand is strong enough to hold
the weight of the fireplace (up to 140lb [63.5Kg]) and venting.
Figure 16. Dimensions for a corner installation.
2" x 6"
Stud
1
/
2
" (13mm)
Front Facing
18
15
/
16
"
(481mm)
30
5
/
16
"
(770mm)
21
7
/
16
"
(545mm)
6
3
/
8
"
(162mm)
The dimensions for installing a
fireplace in the corner of a room
are given in Figures 16. Refer
to “I
NITIAL
I
NSTALLATION
- V
ENT
C
ONFIGURATIONS
AND
R
ESTRICTOR
S
ETTINGS
” for allowable pipe
lengths.
Do not interfere with the
structural integrity of the walls.
14