Configuration, Line parameters – Verilink PRISM 3111 (34-00242) Product Manual User Manual
Page 66

58
C
HAPTER
4: T
ERMINAL
I
NTERFACE
Reset Errors
Pressing
cleared to zero.
T1 NET/DTE Status
These two fields display the fault status of the network and the far end DTE. They
indicate current fault conditions. They do not indicate that alarm thresholds are
exceeded. Status indications are described in NET /DTE Status: These two fields
display the fault status of the network and the T1 DTE. They indicate current fault
conditions. They do not indicate that alarm thresholds are exceeded. Status
indications are described in Table 4-5.
Near Loops
Displays the loop status of the near element.
Far Loops
Displays the loop status of the far element.
Configuration
The Configuration screens allow you to view and set configuration parameters for
the network elements. To save your changes in a configuration screen, press the
The underlined values are the factory default parameters.
Figure 4-8 Configuration Menu
Line Parameters
The Line Parameters screen (Figure 4-9) allows you to review and set line
parameters for the selected element on the T1 circuit. To send the new line
configuration to the unit, press
selection, or exit the screen.
Table 4-5 Status Indications
Status Description
OK
No errors are currently detected.
ERR
Frame bit errors, CRC errors, or BPVs are detected.
LOS
A loss of signal condition exists.
OOF
An out of frame condition exists.
RAI
Far end is receiving a remote alarm indication signal.
AIS
The far end is receiving an alarm indication signal.
UAS
An unavailable signal state exists due to consecutive severely errored seconds.
Port
Parameters
Alarm
Parameters
TCP/IP
Parameters
Configuration Menu
Management
Parameters
DBU
Parameters
Summary
SNMP
Parameters
Line
Parameters