Dial backup – Verilink PRISM 3111 (34-00242) Product Manual User Manual
Page 14

6
C
HAPTER
1: G
ENERAL
Dial Backup
Connection:
RS-232, 10-pin modular
Backup Service:
external PSTN device
Configuration:
Information for backup unit is stored in unit and transmitted
to backup unit by inband AT commands
Dialing:
Numbers programmed and stored in unit and transmitted to
backup unit by inband AT commands or DTR dialing
(assertion)
Restoral:
Manual or automatic restoral to leased line service
Diagnostics
Performance:
Monitoring per TR 54016 and T1.403
Network Loops:
Line loopback, payload loopback, or maintenance loopback
Fractional Loop:
Generates and responds to inband V.54 loop code
DTE Port Loops:
Bidirectional loop toward DTE and Net
T1 DTE Loops:
Line loop; Maintenance loop toward DTE
BERT:
Multiple test patterns toward network or DTE ports
Alarms
Activation:
Programmable thresholds (0-900 seconds)
Reporting:
Front panel LEDs, call out on alarm (COA), SNMP traps
Power
115 VAC:
120 mA, 7 W maximum, 24 BTU maximum
48 VDC:
180 mA, 9 W maximum, 31 BTU maximum
Mechanical
Mounting:
Desktop or horizontal rack
Dimensions:
Width 11.75 inches (29.84 cm)
Height 1.75 inches (53.34 cm)
Depth 9.5 inches (24.136 cm)
Weight:
3 pounds (1.36 kg)
Environmental
Operating Temp:
32
°
to 122
°
F (0
°
to 50
°
C)
Storage Temp:
-4
°
to 185
°
F (-20
°
to 85
°
C)
Humidity:
95% maximum (non -condensing)
Standards
TR62411:
December 1990
TR54016:
September 1989
ANSI T1.403:
1989
TR54019A:
April 1988
Ethernet:
ISO /IEC 8802-3
Token Ring:
ISO /IEC 8802-5