Supv prt parms, Coa con, Channel allocation – Verilink PRISM 3111 (34-00242) Product Manual User Manual
Page 48

40
C
HAPTER
3: F
RONT
P
ANEL
I
NTERFACE
Trap 1 - 6 IP Addr
Accepts the IP address of a network device where alarm reporting traps are to be
sent. The unit detects and reports alarms and provides several options for reporting
them including SNMP traps. When a network alarm occurs, the unit sends a trap
message to up to six destinations on the network. This field allows you to enter the
Trap IP address consisting of four octets separated by periods. Each value has a
range from 0 to 255 (Figure 3-16).
Read Community
Accepts a character string of up to 58 characters identifying the group authorized
to perform read operations as displayed in Figure 3-17. The default is public.
Figure 3-17 System Edit
Write Community
Accepts a character string of up to 58 characters identifying the group authorized
to perform write operations. The default is a null string.
Sys Contact
The System Contact field accepts a character string of up to 58 characters
identifying the person responsible for a network device. The default is no system
contact.
Sys Name
The System Name field accepts a character string of up to 58 characters
identifying the functionality of the network device. The default is no system name.
Sys Location
The System Location field accepts a character string of up to 58 characters
identifying the physical location of network device. The default is no system
location.
Manage Ports
The Management Ports screen sets the following parameters for the Call On Alarm
(COA) connection on both the SUPV and SLIP ports.
Element ID
This field allows the entry of an ASCII string (29 characters in length) which
identifies the unit to the device receiving the alarm notification messages.
SUPV Prt Parms
COA Con.
This field controls the remote alarm reporting. ASCII alarm reporting
through the supervisory port is independent of trap alarm reporting. Call on alarm
messages are reported in the following format in the Dial or Direct modes only:
Element ID HH:MM:SS MM/DD/YY
Read Community
>public