Sync tme biterr errsec synlos reset, Configuration, T1 net params – Verilink PRISM 3111 (34-00242) Product Manual User Manual
Page 40: Framing

32
C
HAPTER
3: F
RONT
P
ANEL
I
NTERFACE
Ch 1 - 24 - BERTs the selected channel towards the network. Only un-allocated
channels are available for selection.
Sync
Displays the current state of pattern sync during a test. Values are:
No Sync - Test is active, but the receiver is not in pattern sync.
In Sync - The receiver is in pattern sync. An error may be occurring.
No Test - No test is in progress.
Tme
Displays the elapsed time since the BERT began. A value is displayed only when a
test is running. The format is HH:MM:SS.
BitErr
Displays the total number of bit errors detected since the test began or since error
statistics were last cleared.
Errsec
Displays the number of errored seconds that have been detected since the test
began or since error statistics were last cleared.
SynLos
Displays the number of times during the test period that the BERT pattern detector
lost pattern sync.
Reset
This selection allows you to reset the BERT data.
Configuration
The Configuration menu (Figure 3-15) allows you to establish setup parameters.
Figure 3-15 Configuration Menu
T1 Net Params
This menu establishes the necessary parameters for connection with the T1
network.
Framing
Selects the type of framing for the network interface as either ESF or D4.
T1 Net Params
T1 DTE Params
Port 2 Params
DBU Params
Port 1 Params
Configuration
TCP/IP Params
Manage Ports
SNMP Params