Alarms
The Alarms screen (Figure 4-3) allows you to view the current alarm status of the
network and the DTE interfaces.
Figure 4-3 Alarms Screen
Net Alarms
These status lines display the selected element’s current network signal alarm state
(Table 4-2). Alarms are determined by the selectable thresholds in the Alarm
Configuration screen on page 61.
Table 4-2 NET Alarm Indicators
Alarm
Description
OK
No alarm threshold has been exceeded, although errors may exist which do not
exceed thresholds.
ERR
The Errored Seconds, Severely Errored Seconds, or Bipolar Errored Seconds
threshold is exceeded.
LOS
The Loss Of Signal Seconds threshold is exceeded.
OOF
The Out Of Frame Seconds threshold is exceeded.
RAI
The Remote Alarm Seconds threshold is exceeded.
AIS
The Alarm Indication Seconds threshold is exceeded.
UAS
The Unavailable Seconds threshold is exceeded.
TST
Unit is in BERT or loop condition.
DBA
Dial Backup Active
DBF
Dial Backup Failed