NetEngine IAD User Guide
Voice Path Configuration
163
4. Reset the IAD (page
) when you finish voice path configuration.
Changing the Maximum CPS-SDU Size
1. Type
S
to switch the maximum CPS payload size between 45 and 64
octets.
2. The IAD displays the AAL2/LES Manual Configuration menu. Included
in the settings is a payload size message indicating 45 or 64 octets.
3. Reset the IAD (page
) when you finish voice path configuration.
Setting the Combined Use Timer
1. Type
T
to modify the combined use timer (in 5 ms increments). The
IAD displays this prompt:
New "Combined Use" timer period in 5ms increment:
Type the new timer period and press Enter.
2. The IAD updates the setting and displays the menu.
3. Reset the IAD (page
) when you finish voice path configuration.
Enabling and Disabling User State Control
1. Type
U
to enable or disable user state control by toggling the state.
2. The IAD displays the AAL2/LES Manual Configuration menu. Included
in the settings is a USC message indicating that it is enabled or
disabled.
3. Reset the IAD (page
) when you finish voice path configuration.
Enabling and Disabling Dialed Digit
1. Type
D
to enable or disable dialed digit by toggling the state.
2. The IAD displays the AAL2/LES Manual Configuration menu. Included
in the settings is a message indicating that dialed digit will be enabled
or disabled after reset.
3. Reset the IAD (page
) when you finish voice path configuration.
Setting ATM Pace Control Manually
Type
A
to set ATM Pace Control manually. The IAD displays this menu:
Figure 7–24. Manual ATM Pace Control Menu
Type the option for the command to execute and proceed to the
appropriate section.
Enabling and Disabling Manual ATM Pace Control
1. Type
P
to enable or disable pace control.
2. The IAD displays:
************************************
Manual ATM Pace Control
************************************
Manual ATM pace control is disabled
Audio bit rate margin is 0%
Minimum signaling bit rate is 0bps
P. Manual ATM Pace Control
A. Audio Bit Rate Margin
M. Minimum Signaling Bit Rate