1-2
G
ENERAL
The unit may be controlled through a VT100 terminal or a computer with ANSI
terminal emulation software. If used with the EM8000 Element Manager or 8100A
Site Controller, the entire T1 network can be monitored and controlled from a
central location.
LED indicators are provided on the front panel of the unit to alert local personnel
of alarm conditions, loop and test status, and DTE port activity. A test switch
allows local and remote loops to be activated as well as BERT tests. Although all
configuration parameters are software selectable from the terminal interface or the
network manager, configuration switches are provided on the unit to allow
operation without the use of a management interface.
Features
✦
Stand-alone housing or chassis nest mounting
✦
Integral full function D4 /ESF CSU
✦
Multiple loopback functions including BERT test patterns and in-band
fractional loops
✦
Selectable facility ALBO levels and DTE DSX levels
✦
Flash memory allowing field upgrades of firmware
✦
Selectable alarms, programmable alarm parameters and monitoring, and isolated
alarm relay contacts
✦
High-speed data port supporting both internal and external clocking
✦
Thirty day storage of T1 line performance information
✦
Optional EM8000 Element Manager and 8100A Site Controller
Specifications
Network
Interface
Line Rate:
1.544 Mbps, ± 50 ppm
Line Framing:
D4 or ESF
Line Code:
AMI or B8ZS
Input Signal:
DS1, 0 to -27 dB ALBO
Connection: RJ-48C
modular
jack (100
Ω,
± 5%) or terminal block
Output Signal:
DS1, 3.0 V (±10%) base-peak into 100
Ω
with protection
Line Build Out:
0, -7.5, -15, and -22.5 dB attenuation
Line Protection:
1000 V lightning, fused input and output
Jitter Control:
per TR62411 and T1.403
Pulse Density:
15 or 175 zeros
Timing Source:
Internal, recovered line clock, station clock, external DTE