beautypg.com

Features -2, Specifications -2, Network interface -2 – Verilink PRISM 3001 (34-00186) Product Manual User Manual

Page 6: Specifications

background image

1-2

G

ENERAL

The unit may be controlled through a VT100 terminal or a computer with ANSI
terminal emulation software. If used with the EM8000 Element Manager or 8100A
Site Controller, the entire T1 network can be monitored and controlled from a
central location.

LED indicators are provided on the front panel of the unit to alert local personnel
of alarm conditions, loop and test status, and DTE port activity. A test switch
allows local and remote loops to be activated as well as BERT tests. Although all
configuration parameters are software selectable from the terminal interface or the
network manager, configuration switches are provided on the unit to allow
operation without the use of a management interface.

Features

Stand-alone housing or chassis nest mounting

Integral full function D4 /ESF CSU

Multiple loopback functions including BERT test patterns and in-band
fractional loops

Selectable facility ALBO levels and DTE DSX levels

Flash memory allowing field upgrades of firmware

Selectable alarms, programmable alarm parameters and monitoring, and isolated
alarm relay contacts

High-speed data port supporting both internal and external clocking

Thirty day storage of T1 line performance information

Optional EM8000 Element Manager and 8100A Site Controller

Specifications

Network

Interface

Line Rate:

1.544 Mbps, ± 50 ppm

Line Framing:

D4 or ESF

Line Code:

AMI or B8ZS

Input Signal:

DS1, 0 to -27 dB ALBO

Connection: RJ-48C

modular

jack (100

Ω,

± 5%) or terminal block

Output Signal:

DS1, 3.0 V (±10%) base-peak into 100

with protection

Line Build Out:

0, -7.5, -15, and -22.5 dB attenuation

Line Protection:

1000 V lightning, fused input and output

Jitter Control:

per TR62411 and T1.403

Pulse Density:

15 or 175 zeros

Timing Source:

Internal, recovered line clock, station clock, external DTE