T1 dte switch s8 -8 – Verilink PRISM 3001 (34-00186) Product Manual User Manual

Page 22

background image

2-8

I

NSTALLATION

20 out of the 24 possible bit rate configurations are available through these
hardware settings. The missing rates are N

×

56 and N

×

64, where N = 15, 17, 21,

and 23. All 24 rate configurations can be programmed through software control by
using the NMS or supervisory ports. The terminal interface program also allows
the high-speed port to be mapped to a block of DS0s that begins at a user-
selectable starting channel.

For units equipped with the T1 DTE port option, channel numbers beyond those assigned
to the high-speed port are automatically mapped through to the T1 DTE. In the alternate
channel mode, every data channel is followed by an idle channel assignment. Therefore,
the even channels are quiet and are not available to the T1 DTE port.

T1 DTE

Switch S8

The optional T1 DTE port circuit board allows for drop and insert applications.
DIP Switch S8 is located on this board which is on the opposite side of the unit
from the main circuit board).

T1 DTE Line Framing

Position S8-1 is used to set the framing of the T1 DTE line.

Down: ESF

Up: D4

T1 DTE Line Coding

Position S8-2 sets the line coding for either AMI or B8ZS zero suppression.

Down: AMI

Up: B8ZS

T1 DTE LBO

Positions S8 -3, S8-4, and S8 -5 set the line build out to one of the values listed
below. The transmit output level is selectable according to the cable length
between the unit and the T1 equipment (PABX, channel bank, etc.). The factory
default setting is 0 -110 feet.

Table 2-7 T1 DTE Line Build Out

S8-3

S8-4

S8-5

DTE LBO

Down

Down

Down

0 -110 ft

Up

Down

Down

110-220 ft

Down

Up

Down

220-330 ft

Up

Up

Down

330-440 ft

Down

Down

Up

440-550 ft

Up

Down

Up

550-655 ft

Down

Up

Up

> 655 ft