Rate multiplier -7 s6-8 -7, Rotary switch s7 -7 – Verilink PRISM 3001 (34-00186) Product Manual User Manual
Page 21

Unit Configuration
2-7
NET Framing:
ESF
DTE Framing:
ESF
NET Line Code:
AMI
DTE Line Code:
AMI
Timing:
Internal
NET LBO:
0 dB
DTE DSX level:
0 - 110 feet
PRM Enable:
Disabled
Zero Suppression:
Enabled
high-speed Port:
Disabled
Rate Multiplier
Position S6-7 is used to set the multiplier for the input timing. The unit can
operate at any data rate that is a multiple of 56 or 64 kbps. Selecting N
×
64K
provides port bit rates that are multiples of 64 kbps. The ones density requirements
of the T1 network line must be ensured in this mode. Selecting N
×
56K allows port
bit rates that are multiples of 56 kbps. The unit maintains ones density for the
selected DS0 channel in this mode.
Down: N
×
64 K Up: N
×
56K
S6-8
This switch is not used.
Rotary
Switch S7
This 10-position rotary switch works in conjunction with S6-7 and S4-8 to select
high-speed port bit rates. Switch S6 -7 selects the rate multiplier as either N
×
64 or
N
×
56 (refer to Rate Multiplier in the previous paragraph).
Switch S4-8 selects either the Contiguous or Alternate mode for the network DS0s
to carry data (refer to Channel Assignment in Configuration Switch S4 on page
2-3). Switch S4-5 is used to select the bit rates as shown in Table 2-6
.
Table 2-6 High-speed Port Bit Rates
Switch
S7
w/S4-5 down w/S4-5
up
×
56
×
64
×
56
×
64
0 56
64 168
192
1
112 128 280 320
2
224 256
392 448
3
336 384 448 512
4
560 640 504 576
5
672 768 616 704
6
1008
1152 728 832
7
1120
1280 784 896
8
1232
1408 896
1024
9
1344 1536 1064
1216