I

NSTALLATION

T1 DTE Port
Connection

The 3001 provides an optional T1 DTE port interface for drop and insert applications.
The DSX-output level should be set as instructed in T1 DTE LBO on page 2-8.

The DTE physical interface for both the stand -alone unit and the chassis mounted
unit is a standard RJ-48C 8- pin modular jack with the pinout shown in Table 2-11.

Network
Connection

The network side of the 3001 is referred to as the network interface. This interface
contains an ALBO to allow the unit to be located a substantial distance away from
the telco network interface (receive level to -27 dB).

The network interface line build out levels should be adjusted as instructed in
Network LBO on page 2 -4. The maximum suggested cable lengths for unit
connection to the network are listed below. Calculations are based on a cable
temperature of 70°F, 0.083-

µ

F/mile capacitance, a 27-dB loss, and a 100-

,

non-loaded, twisted pair cable. PIC refers to plastic insulated cable.

The network physical interface for both the stand-alone unit and the chassis
mounted unit is a standard RJ-48C 8- pin modular jack with the pinout shown in
Table 2-13.

Table 2-11 T1 DTE Pinout

Pin

T1 DTE Interface

1

Data Out

2

Data Out

3

Not Used

4

Data In

5

Data In

6

Not Used

7, 8

Chassis Ground

Table 2-12 Network Line Build Out

Cable Type

Loss per 1000'

Max Cable Length

26 gauge PIC

6.8 dB

3,900 ft

24 gauge PIC

5.4 dB

5,000 ft

22 gauge PIC

4.2 dB

6,400 ft

19 gauge PIC

3.0 dB

9,000 ft

Table 2-13 Network Pinout

Pin

Network Interface

1

Data In

2

Data In

3

Not Used

4

Data Out

5

Data Out

6

Not Used

7, 8

Chassis Ground