NMS Bit Rate

Positions S6 -1 and S6-2 are used to set the NMS port bit rate. This is a serial
RS-232 DCE port configured for 8 bits, no parity, and 1 stop bit. The table below
shows the available speeds.

Supervisory Port Bit Rate

Positions S6 -3 and S6-4 are used to set the supervisory port bit rate. This is a
serial RS-232 DCE port configured for 8 bits, no parity, and 1 stop bit. Table 2-4
shows the available speeds.

Boot Mode

Positions S6 -5 and S6-6 are used to set the power up configuration mode as
shown in Table 2-5.

Boot from switch settings.

Upon reset, the unit reads its configuration from all the

hardware switch settings.

Boot from RAM.

Upon reset, the unit reads its configuration from the internal,

battery -backed RAM.

Boot from manager.

Upon reset, the unit requests configuration information from

the manager. If the manager is not on-line, the unit boots from RAM.

Boot from ROM.

Upon reset, the unit reads its configuration from the internal

ROM. The ROM factory default settings are as follows.

Table 2-3 NMS Port Bit Rate

S6-1

S6-2

NMS Port Bit Rate

Down

Down

19200 bps

Up

Down

9600 bps

Down

Up

2400 bps

Up

Up

1200 bps

Table 2-4 SUPV Port Rate

S6-3

S6-4

SUPV Port Rate

Down

Down

19200 bps

Up

Down

9600 bps

Down

Up

2400 bps

Up

Up

1200 bps

Table 2-5 Boot Mode

S6-5

S6-6

Power-up Mode

Down

Down

Boot from switch settings

Up

Down

Boot from RAM

Down

Up

Boot from manager

Up

Up

Boot from ROM