Verilink AS4000 User Manual

9-5

Table 9-1

Link Configuration Fields

Field

Description

Link Number

Displays the link number selected from the Link Configuration menu.

Name

(text field)

This is a user-defined field. Any name up to 20 characters in length can be

entered to identify each port on the Octal DS-1/E1. Some users find it beneficial

to use circuit numbers to name the ports.

Status

(option field)

This field determines the status of the port. The status will either be In Service or

Out of Service.

• In Service - an operational link that shows a valid configuration has been set

up. When the port is In Service you can run Diagnostics.

• Out of Service - a mechanism to avoid getting alarms. Out of Service also

causes the port to be inactive and you cannot run Diagnostics.

Line Type

(option field)

This field determines the type of framing used on the line. The line types are as

follows:

1. Short Haul and Long Haul line interface options are available with E1 line

types (i.e., how long the line is coming from your facility).

• E1

• E1-CRC

• E1-CAS

• E1-CAS-CRC

• E1-Unframed

2. An LBO option field is available with T1 line types.

• T1-ESF AMI 62411

• T1-ESF B8ZS Clear

• T1 D4 B8ZS Clear

• T1 D4 AMI 62411

• T1 over E1

Network Loop

(option field)

This entry determines the module’s ability to respond to loop diagnostic

commands received from the network supplier. (Enabled/Disabled) The default

setting is Disabled.