beautypg.com

Tri Tool 206B Beveler User Manual

Page 34

background image

34

TRI TOOL INC.

92-0211 : Rev. 050224

Problem:

There's a Loss of Air Power

The air supply pressure is too low.
The air filter is plugged.
The air line size is insufficient.
The air line is too long.

Problem:

There's a Loss of Hydraulic Power

The hydraulic supply pressure is too low.
The hydraulic filter is plugged.
The hydraulic line size is insufficient.
The hydraulic line is too long.

Problem:

The Tool Bit Will Not Reach the Work

Incorrect tool blocks are installed for the size of the pipe or tube being worked
on.
Incorrect tool bit is installed.

Problem:

The Hydraulic Motor Will Not Start

The hydraulic power supply is shut off.
The hydraulic motor is damaged and will not run free.