PARAMETER DOWNLOAD
START AUTO

AUTO DOWNLOAD=ENABLED
ENABLE DISABLE

SPID Entry __________________________________________________

A unique SPID (Service Profile IDentifier) is required for operation of the 8810. If the network supports
AutoSPID, a SPID that is assigned to your ISDN line can be automatically selected. If National ISDN
generic SPID assignments are used by your service provider, your SPID will consist of your primary
telephone number followed by “0101” (e.g., 42534910000101). Contact your network service provider for
your telephone’s SPID.

From the Installation Options menu, select SPID.
(

SETUP

→ INSTL → SPID)

Using the dial pad, enter the SPID number supplied by your network service provider.
If you need to make corrections, select

Å

BKSP (backspace) to delete the previous digit.

CLEAR removes all digits, allowing you to start over.

When digits have been entered, press the

OK

key to return to the Installation Options menu or

press the

SETUP

key to exit Setup Mode.

Parameter Download (National ISDN only) ________________________

ISDN Parameter Download is an automated feature for configuring Call Appearance and Feature Activator
keys. If configured for auto download, a Parameter Download is executed when the phone initializes with a
new SPID, or when requested by the network, due to a line configuration change.

Note

: Speed Dial and DSS keys are not configured by Parameter Download.

From the Installation Options menu, select PARAM.
(

SETUP

→ INSTL → PARAM)

Starting a Download

Select START to manually initiate a Parameter Download.

Note

: Customized key labels will not be overwritten unless the network configuration for that key

is changed. To revert a key label to the network default, clear the label before initiating a
Parameter Download – see page 23.

Enabling/Disabling Automatic Download

Select AUTO.