beautypg.com

Perform firmware recovery – Teletronics EZStation5 User Manual

Page 167

background image

Page 167

Perform Firmware Recovery


If the system fails to launch properly, the access point will automatically

switch to loader mode and the diagnostic LED will remain lighted. The
firmware should then be reloaded.

Access Point State

Diagnostic LED ( ) State

Corrupted firmware – access point
automatically switches to loader mode

Blinks very fast

Recovery in progress

ON

Successful recovery

Blinks very slowly


Before starting, check the status of the diagnostic LED to confirm if

firmware failure has occurred.

S

S

t

t

e

e

p

p

1

1

:

:

Stop power supply and disconnect the access point from the network.

S

S

t

t

e

e

p

p

2

2

:

:

Connect the LAN port of the access point to the LAN port of your
computer with an MDI cable.

S

S

t

t

e

e

p

p

3

3

:

:

Power on the access point, and start up your computer. You are
recommended to set your computer’s IP address to 192.168.168.100 and
its network mask to 255.255.255.0.

It is recommended that your computer IP address is set to 192.168.168.100
and the network mask is set to 255.255.255.0

S

S

t

t

e

e

p

p

4

4

:

:

Insert the Product CD into the CD drive of your computer.