Test faucet operation – Sloan ETF-500 Faucet User Manual
Page 7

7
Time Out Adjustment
The Faucet Time Out Setting determines the maximum time the Faucet will
run upon continuous activation. This timing can be changed to meet
individual application requirements.
Refer to Table 1 or label on cover of Control Module along with the
following instructions to set the desired Time Out. The Dip Switches used
to set the Time Out are located in the Control Module.
Set the Time Out by configuring the number 1, 2 and 3 Dip Switches as
shown in Table 1.
Table 1 — Time Out Settings
Unless otherwise specified, all ETF-500/ETF-700 Faucets leave the factory
set with a 30 second Time Out.
Note: The position of Dip Switch # 4 (range enhancer setting) does not
affect Faucet Time Outs.
Push Cables into slots at the bottom of the Control Module.
Install Control Module Cover using Screws provided. Refer to illustration in
Step 7.
Time Out
Dip Switch Setting
Switch #1
Switch #2
Switch #3
3 SECONDS
UP
UP
DOWN
6 SECONDS
DOWN
DOWN
UP
12 SECONDS
UP
DOWN
UP
30 SECONDS
UP
DOWN
DOWN
45 SECONDS
UP
UP
UP
1 MINUTE
DOWN
UP
UP
3 MINUTES
DOWN
DOWN
DOWN
20 MINUTES
DOWN
UP
DOWN
1. A continuous invisible beam of
infrared light is emitted from the
OPTIMA sensor located at the
base of the lavatory faucet.
2. As the user’s hands enter the
beam’s effective range (beneath
the spray head), the beam is
reflected back into the sensor
receiver and activates the
solenoid valve. Tempered water
flows from the faucet into the
sink until the hands are removed
from the beam or until the faucet
reaches an automatic time out
limit setting.
3. When hands are moved away
from the sensor, the loss of
reflected light initiates an
electrical signal that deactivates
the solenoid valve, shutting off
the water flow. The circuit then
automatically resets and is ready
for the next user.
Test Faucet Operation
9
Range Adjustment (continued)
CARE AND CLEANING OF CHROME
AND SPECIAL FINISHES
DO NOT use abrasive or chemical cleaners (including chlorine bleach) to
clean faucets that may dull the luster and attack the chrome or special
decorative finishes. Use ONLY soap and water, then wipe dry with clean
cloth or towel.
When cleaning the bathroom tile, protect the faucet from any splattering of
cleaner. Acids and cleaning fluids will discolor or remove chrome plating.
ETF-500