Sloan 910 Royal Exposed 900 Hydraulic Series User Manual
Page 3

3
WITH THE EXCEPTION OF THE CONTROL STOP INLET,
DO NOT USE PIPE THREAD SEALANT OR PLUMBING
GREASE ON VALVE COMPONENTS OR COUPLINGS.
PROTECT THE CHROME OR SPECIAL FINISH OF SLOAN’S
FLUSHOMETERS. DO NOT USE TOOTHED TOOLS TO INSTALL OR
SERVICE VALVES. USE A SLOAN A-50 SUPER WRENCH™, SLOAN
A-109 PLIER WRENCH OR SMOOTH JAWED SPUD WRENCH TO
SECURE COUPLINGS. SEE “CARE AND CLEANING” SECTION FOR
MORE DETAILS.
NEVER OPEN THE CONTROL STOP TO WHERE THE FLOW FROM
THE VALVE EXCEEDS THE FLOW CAPABILITY OF THE FIXTURE. IN
THE EVENT OF A VALVE FAILURE, THE FIXTURE MUST BE ABLE TO
ACCOMMODATE A CONTINUOUS FLOW FROM THE VALVE.
THIS PRODUCT CONTAINS MECHANICAL AND THAT ARE SUBJECT
TO NORMAL WEAR. THESE COMPONENTS SHOULD BE CHECKED ON
A REGULAR BASIS AND REPLACED AS NEEDED TO MAINTAIN THE
VALVE’S PERFORMANCE.
!!! IMPORTANT !!!
!!! IMPORTANT !!!
!!! IMPORTANT !!!
!!! IMPORTANT !!!
A
Slide the spud coupling, nylon slip gasket, rubber gasket and
spud flange over the vacuum breaker tube.
VACUUM
BREAKER
ELBOW
FLUSH
CONNECTION
RUBBER
GASKET
NYLON
SLIP
GASKET
B
Insert tube into fixture spud. Hand tighten spud coupling
onto fixture spud.
VACUUM
BREAKER
TUBE
SPUD
COUPLING
SPUD
COUPLING
NYLON
SLIP
GASKET
RUBBER
GASKET
SPUD
FLANGE
SPUD
FLANGE
MODELS
920, 921 & 922
MODELS
910, 913, 915,
916 & 917
MODEL
980
MODEL
986
VACUUM
BREAKER
TUBE
SPUD
COUPLING
NYLON
SLIP
GASKET
RUBBER
GASKET
SPUD
FLANGE
A
Measure from finished wall to C/L of Fixture Spud. Cut pipe 1¼” (32
mm) shorter than this measurement. Chamfer O.D. and I.D. of water
supply pipe.
WATER SUPPLY PIPE
FINISHED WALL
1-1/4”
(32 mm)
C/L OF
FIXTURE
SPUD
SWEAT
SOLDER
ADAPTER
B
Slide Threaded Adapter fully onto pipe.
C
Sweat solder the Adapter to pipe.
BAK-CHEK
®
CONTROL STOP
COVER TUBE ‡
IRON PIPE NIPPLE OR
COPPER PIPE WITH SWEAT
SOLDER ADAPTER
SET SCREW
SUPPLY
FLANGE ‡
WATER
SUPPLY PIPE
SWEAT SOLDER
ADAPTER
COVER TUBE
WALL
FLANGE
SET SCREW
A
Measure from finished wall
to first thread of adapter
or threaded supply pipe
(dimension “X”). Cut cover tube
to this length.
B
Slide cover tube over pipe.
Slide wall flange over cover
tube until against wall.
Install the Sloan Bak-Chek
®
control stop to the water supply
line with the outlet positioned
as required.
C
Tighten Set Screw with a 1/16”
hex wrench. DO NOT install vandal
resistant stop cap at this time.
D
‡ Cover Tube
and Supply
Flange with
Set Screw is
supplied with
Royal valves;
available in
“YBYC” Sweat
Kit for Regal
valves.
1 - INSTALL OPTIONAL SWEAT SOLDER ADAPTER (ONLY IF YOUR SUPPLY PIPE DOES NOT HAVE A MALE THREAD)
2 - INSTALL COVER TUBE, WALL FLANGE, AND CONTROL STOP TO SUPPLY PIPE
3 - INSTALL VACUUM BREAKER FLUSH CONNECTION
When further assistance is required, please consult your local Sloan
Representative, or Sloan Technical Support at:
1-888-SLOAN-14 (1-888-756-2614)
- 911 Royal Exposed 900 Hydraulic Series 986 Royal Exposed 900 Hydraulic Series 920 Royal Exposed 900 Hydraulic Series 917 Royal Exposed 900 Hydraulic Series 980 Royal Exposed 900 Hydraulic Series 922 Royal Exposed 900 Hydraulic Series 921 Royal Exposed 900 Hydraulic Series 913 Royal Exposed 900 Hydraulic Series 915 Royal Exposed 900 Hydraulic Series 916 Royal Exposed 900 Hydraulic Series