beautypg.com

Powered tests – Seaward Europa Pac Plus User Manual

Page 32

background image

Powered Tests

26

next digit in turn to flash. Use the cursor buttons to set a value for this
flashing digit. Then press the SELECT button to move to the next
digit. Repeat these actions until all digits are set to your chosen
value. Press the STORE RESULT button to set the limit.

Press the SELECT button to change to another setting or press the
START/STOP button to perform the test if the other settings are
acceptable.

Powered Tests

Warning

Mains voltage applied to appliance

The following powered tests differ from the previous tests in that they
apply mains supply voltage to the appliance to perform their
functions:-

• Differential

Leakage

• Touch Leakage
• Load

Note

These tests are not available when using the 110v adaptor.

The Tester performs an initial low voltage test to establish that the
appliance can be safely powered.

When the rotary switch is rotated through the different power tests
the power supply is not interrupted but the test counter is reset. This
allows the user to obtain results from all three tests without having to
interrupt the power. To abort a power test rotate the knob beyond the
power tests.

Warning

It is important that the user verifies that an appliance

with moving parts (e.g. an electric drill) is safely

mounted to allow movement without causing damage to

equipment or personnel.