beautypg.com

For the plumber, Conform to all applicable codes, Water inlet – Scotsman NME654R User Manual

Page 9: Drains

background image

FOR THE PLUMBER

CONFORM TO ALL APPLICABLE CODES

Water Inlet

The recommended water supply is

cold water. Use 3/8" O.D. copper

tubing, connect to the 3/8" male flare

at the back of the cabinet. Install a

hand valve near the machine to

control the water supply.

Drains

There is one ¾ " FPT drain at the

back of the cabinet, the drain line is of

the gravity type, and ¼ inch per foot

fall is an acceptable pitch for the drain

tubing. There should be a vent at the

highest point of the drain line, and the

ideal drain receptacle would be a

trapped and vented floor drain. Use

only ¾ " rigid tubing.

Storage Bin: Install a separate

gravity type drain. Insulation of this

drain line is recommended.

NME654R & FME804R

January 2000

Page 9

FLOOR DRAIN

VENT BIN DRAIN

3/4" FPT

VENT ICE

MACHINE

DRAIN, 3/4"

FPT

WATER INLET

3/8" MALE

FIELD SUPPLIED

WATER FILTER

HAND SHUT

OFF VALVE

CONNECT TO

COLD WATER