FOR THE ELECTRICIAN

CONFORM TO ALL APPLICABLE CODES

Connect the electrical power to the unit to the wires

in the junction box at the rear of the machine.

Check the nameplate (located on the back panel)

for the voltage requirements, and for the minimum

circuit ampacity. The machine requires a solid

chassis to earth ground wire.

Connect the ice machine to its own electrical circuit

so it is individually fused. Voltage variation must

remain within design limitations, even under

starting conditions.

There is a separate junction box for the remote

condenser fan motor.

Install an interconnecting wire between the remote

condenser and the junction box at the back of the

ice machine.

The remote condenser must be wired to the ice

machine in accordance with local and national

electrical codes with a minimum of 18 Awg. wire

with an ground bonding wire connected to the

ground screws provided in both the condenser and

machine field wiring boxes. All outdoor wiring must

be in rainproof conduit.

All external wiring must conform to national,

state, and local electrical codes. The use of a

licensed electrician is required to perform the

electrical installation.

NME654R & FME804R

January 2000

Page 10

TERMINAL STRIP

FOR REMOTE

CONDENSER

ICE MACHINE

JUNCTION BOX

POWER

SUPPLY

GROUND

THE

CHASSIS

RAIN PROOF

CONDUIT