Service diagnosis – Scotsman NME654R User Manual

Page 27

background image

NME654R & FME804R

January 2000

Page 27

No ice, auger motor is turning

Compressor contactor coil is open

Check / replace contactor

Compressor will not start

Check start capacitor
Check start relay
Check compressor windings

Circuit board relay will not close

Check / replace board

Pump down pressure switch contacts

do not close, liquid line valve open

and suction pressure high

Check pump down switch contacts

Symptom

Possible Cause

Probable Correction

Unit makes ice, but very slowly

High discharge pressure because of a

dirty condenser coil

Clean the condenser

Auger and evaporator are coated with

mineral scale

Clean the water system

Low refrigerant charge

Locate leak. Recover refrigerant,

repair leak, replace dryer, evacuate

and weigh in the nameplate charge.

Water leak

Ice storage bin drain restricted

Clean out drain

Tubing cracked

Replace tubing

Condensation on drain tubing

Insulate tubing

Hose off

Re-attach hose

Reservoir cover off

Return cover to reservoir

Reservoir cracked

Replace reservoir

Evaporator water seal leaks

Check base of evaporator & drip pan.

If the seal leaks, shut off the water,

remove the auger, replace the water

seal. Check gear motor for water

infiltration.

Excessive ice meltage

Bin drain clogged

Clean out bin drain

Poor fit between bin door and door

frame

Adjust or replace

Machine makes too much noise

Evaporator coated internally with

minerals

Clean with Scotsman Ice Machine

Cleaner

Motor bearings dry

Oil or replace motor

SERVICE DIAGNOSIS: