Initial Connections:

1. Remove the protector caps and plugs. Wipe the

seats and threaded surfaces with a clean cloth to

be certain that no foreign matter remains on them.

2. Lubricate the inside of the couplings, especially

the O-Rings with refrigerant oil.

3. Position the fittings on the correct connections

on the condenser and ice machine.

·

The ½ inch discharge line (schrader valve end)

goes to the remote condenser fitting marked

“discharge line.”

·

The

3

8

inch liquid line (schrader valve end) goes

to the remote condenser fitting marked “liquid

line.”

·

The ½ inch discharge line goes to the ice

maker fitting marked “discharge line.”

·

The

3

8

inch liquid line goes to the ice maker

fitting marked “liquid line.”

Final Connections:

4a. Begin by tightening the couplings together by

hand. Continue to turn the swivel nuts by hand until

is is certain that the threads are properly engaged.

4b. Using two wrenches, one to rotate the swivel

nut and one to hold the tubing, tighten each

coupling.

It is CRITICAL that ONLY the NUT on the

pre-charged tube be turned or the diaphragms will

be torn loose by the piercing knives and be loose

in the refrigeration system causing severe

operational problems.

Note: As the coupling is tightened, the diaphragms

in the quick connect couplings will begin to be

pierced. As that happens, there will be increased

resistance to tightening the swivel nut.

4c. Continue tightening the swivel nut until it

bottoms out or a very definite increase in

resistance is felt (no threads should be showing).

Do NOT overtighten.

5. Using a marker or pen, mark a line lengthwise

from the coupling union nut to the bulkhead. Then

tighten the coupling and additional 1/4 turn. As the

nut turns, the line will show when 1/4 turn is made.

6. After all connections are made, and after the

king valve has been opened (do not open at this

time), check the couplings for leaks.

NME654R & FME804R

January 2000

Page 7

FOR THE INSTALLER: Coupling Instructions

SCHRADER

NO SCHRADER

TO REMOTE

TO ICEMAKER

Clean and Lubricate Couplings

Tighten Swivel Nut

Rotate Swivel Nut ¼ Turn More