beautypg.com

Double system rl, Removal and replacement: evaporator – Scotsman FME24RLM User Manual

Page 25

background image

To Replace the Evaporator:

(Assuming all the steps for removal of the thrust

bearing, breaker, auger, and water seal have been

performed.)

1. Shut the hand valves in the liquid and suction

lines to the evaporator being serviced; then

discharge the refrigerant.

2. Unsweat the refrigerant connections:

a) At the thermostatic expansion valve outlet.

CAUTION

Heat sink the TXV body when unsweating or

resweating the adjacent tubing.

b) At the suction line at the joint about 3" from the

evaporator.

3. Remove the

evaporator.

4. Unsweat the drier

from the liquid line.

5. After installing a

new water seal in the

new evaporator (see

“To Replace the Water

Seal”) sweat in the

new evaporator at the

old connections.

6. Install an new drier

in the liquid line.

7. Evacuate the

system until

dehydrated, then

weigh in the

nameplate charge.

Check for leaks.

8. Install auger,

breaker, breaker

bearing assembly, and

ice discharge chute in

reverse order of

disassembly. See “To

Reassemble

Evaporator and Auger”

To Reassemble the Evaporator and Auger

1. After the gearmotor has been inspected, fasten

the evaporator to the gear motor, torque the bolts

to 110 inch pounds.

2. Lower the auger into the evaporator barrel,

slightly turning it to match up with the drive end. Do

Not Drop Into the Evaporator.

3. Complete the reassembly by reversing the

disassembly for the breaker & thrust bearing

assembly.

Double System RL

November 2000

Page 25

REMOVAL AND REPLACEMENT: Evaporator

ICE SWEEP

BEARING

AUGER

EVAPORATOR

DRIP PAN

DIVIDER/BREAKER