beautypg.com

Double system rl, Removal and replacement: bearing and breaker – Scotsman FME24RLM User Manual

Page 22

background image

REMOVAL AND REPLACEMENT: Bearing And Breaker

Note: Removal of the auger, water seal, evaporator

and gearmotor must begin at the top of the

assembly.

To Remove the Breaker Bearing Assembly:

1. Remove panels and disconnect electrical power.

2. Push back bail clamp, remove insulation

retaining strap and insulation, remove ice chute

cover.

3. Unscrew and remove ice sweep.

4. Lift up and remove ice chute.

5. The breaker may be removed from the auger

and evaporator without disturbing the auger.

a. Unscrew breaker cover from breaker (left hand

threads)

b. Unscrew auger stud from top of auger.

c. Unscrew 4 allen head cap screws holding

breaker to evaporator.

d. Lift up, and remove breaker/bearing assembly

from auger & evaporator.

6. Service the bearing. Check for rust, rough spots

and damage.

a. The bearing is pressed into the breaker, to

remove the bearing and replace it an arbor press is

needed.

b. Replace lower seals before installing new

bearing in breaker.

Note: seals must be pressed in with a tool pushing

against the outer edge only, they will not install by

hand.

Replace parts as required. Re-grease bearing with

Scotsman part no. A36808-001 bearing grease.

Replace top seal, and check the o-rings, replace if

cut or torn.

7. Reverse to reassemble: specific tools and

materials are required to install properly.

a. Add food grade grease such as Scotsman part

number 19-0569-01 to the seal area before

installing on the auger.

b. Check the seal to shaft areas for cuts, or rough

spots: none are permitted.

Double System RL

November 2000

Page 22

Step 5- a

Step 5-b

Step 5-c and Step 6

ICE SWEEP

BREAKER

COVER

AUGER

STUD

BEARING

SEALS

SLOTTED

COLLAR

DIVIDER

Electrical Shock Hazard

Electrical shock can cause

personal injury. Disconnect

electrical power before

beginning.