BEARING MAINTENANCE

The top bearing in the breaker should also be

checked at least two times per year.

Check the breaker bearing by:

·

removing the ice chute cover

·

unscrewing the ice sweep

·

removing the water shed and the breaker cover

(left hand thread)

·

unscrewing the auger stud

Inspect the bearing. There should be plenty of

grease in sight. If grease is needed the bearing

and breaker should be removed to check the

action of the bearing. It should rotate smoothly.

To remove the breaker take out all four allen head

cap screws and pull the breaker off the auger and

evaporator.

If the bearing only needs grease, inject grease into

the bearing using Scotsman grease needle pn

02-3559-01 and Scotsman bearing grease

cartridge, pn A36808-001. Be sure to inject grease

evenly and thoroughly.

See Removal and Replacement section to replace

bearing or seals.

Reverse to reassemble.

Double System RL

November 2000

Page 16

Chute Cover

Ice Sweep

Off

Breaker Cover

Auger Stud

Cap Screw

Grease

Needle, part

number

02-3559-01.