beautypg.com

Double system rl, Auger maintenance – Scotsman FME24RLM User Manual

Page 17

background image

AUGER MAINTENANCE

In some installations the water supply to the ice

maker will be so concentrated with dissolved

minerals, (such as calcium carbonate) that as ice is

made, the evaporator and auger become coated

with those minerals, requiring a more frequent

cleaning than twice per year. If in doubt about the

condition of the evaporator and auger, the auger

can be removed so the parts can be inspected.

Note: Water filters can filter out suspended solids,

but not dissolved solids. “Soft” water may not be

the complete answer. Check with a water

treatment specialist regarding water treatment.

Switch off electrical power, and shut off the water

supply.

For more information on removal of these parts,

see REMOVAL AND REPLACEMENT.

1. To remove the auger, remove front and top

panel. See Removal And Replacement.

2. Push bail clamp back and remove ice chute

cover.

3. Unscrew and remove ice sweep.

4. Remove ice chute from evaporator.

5. Remove 4 allen head screws holding breaker to

evaporator.

6. Pull up on breaker to remove auger.

Allow the auger to dry, the stainless steel of the

auger and evaporator must be clean and bright.

Clean the auger and evaporator as required. DO

NOT HONE THE EVAPORATOR.

7. Replace the water seal.

8. Reverse to reassemble.

Double System RL

November 2000

Page 17

Note:

Flaker Components Shown, Nugget

Components are Similar

DIVIDER, AUGER

AND SLOTTED

COLLAR

ALLEN HEAD

SCREWS

BREAKER

COVER