Tabber Operation Problems

CONDITION

SOLUTION

Media feeds, but no tab or stamp is applied.

1. Make sure media is feeding against the

Media Guide Fence.

2. Check Media Sensor for proper operation.
3. Check that tabs are present. Are you out of

tabs?

4. Check that tabs are threaded correctly.

Tabber display powers on, but Transport Power
Button won’t turn on when pressed.

1. Check to be sure Emergency Stop switch

is released.

2. Check to be sure Exit Roller Assembly is

closed and locked.

3. Check to be sure Jumper Plug is installed

into Safety Stop connection, located on
sidewall of tabber.

Unwind Drive rollers not advancing tabs/stamps
into Bin.

1. Check to be sure the Power connection

between the Reel Assembly and tabber is
securely connected.

2. Check to be sure unwind rollers are

engaged.

3. Check/Clean Bin Sensor.

Tab web breaking at the Unwind Driver Roller.

1. Tab web wrapping around rollers. Clean

unwind rollers.

2. Tabs not spinning freely on Reel. Reel

improperly installed.

3. Check to be sure the Power connection

between the Reel assembly and tabber is
securely connected.

Tab web breaks at or near Tab Applicator Head
peel point.

1. Tabs not manufactured correctly. Tab

backing cut when tabs were made; as tabs
peel backing is torn. Tab web too weak.

2. Unwind drive rollers not advancing tab

stock. Check that unwind rollers are
engaged. Check Bin Sensor.

3. Check to be sure the Power connection

between the Reel assembly and tabber is
securely connected.

Tabber Stops while tabbing.

1. Speed of tabbing exceeds maximum speed

for the number of tabs being applied.
Slow down tabber.

2. Feeder speed is too fast, leaving too little

gap between pieces. Slow down feeder.

T-750 Tabber Operations Rev. 3/4/08