beautypg.com

Rena T-750 User Manual

Page 30

background image


SETUP AND OPERATION

Select option to edit, or
Press RUN to tab using Job 2.
Status: Setup
# Tabs Length Backing EXIT

If the Length soft key is pressed.
The display will prompt you to enter the piece
length (using the number keypad) or press
“Automatic” for the tabber to automatically
measure the piece length.

ƒ Automatic – “Automatic Piece Length

Measurement”. Media can be fed through the
tabber and measured automatically. This is
the recommended method.

Enter piece length and press SAVE key

Current Value: 6.153”


Automatic

EXIT

ƒ

EXIT

Brings you back to the previous

screen.

Enter piece length and press SAVE key

Current Value: 6.153”


Automatic

EXIT

Press the Automatic soft key.

IMPORTANT: Make sure that the transport
power switch is turned ON.
If the T-750 displays “Increase Transport Speed”
or “Decrease Transport Speed”, adjust the
transport speed until the display shows “Feed 1
Product now”.

Feed 1 Product now
Status:

EXIT

When the display reads “Feed 1 Product now”,
feed one of your mail pieces through the tabber.

Note: Feeding more than one mail piece will cause
an incorrect length to be measured.

The tabber will measure and display the piece
length. Verify the measurement.
It must be accurate (+ or - 0.250”).

If the tabber measures the piece to be longer
then the actual piece length; then the media may
be slipping or hesitating as it feeds.
Check/Adjust the transport system.
If the tabber measures the piece to be shorter than the actual piece length; then the media
may not be feeding straight (missing the sensor), or a hole in the media may be traveling
through the sensor, or the sensor may be getting reflection off the mail piece. If using a high
gloss media, the sensor intensity may need to be adjusted lower by a qualified Rena service
person.
If the media passes through without the tabber providing a measurement; then the media
sensor may be dirty. Try cleaning the sensor as described in this manual.
These problems need to be corrected before the tabber will function correctly.

Enter piece length and press SAVE key
0.00” Current Value: 8.523”
Status: Pieces: 2
Automatic

EXIT

T-750 Tabber Operations Rev. 3/4/08

30