Ptional, Eeder, Onnections – Rena T-750 User Manual
Page 11: Ontrols
GETTING ACQUAINTED
EasyFeed 120 (Optional Feeder) Connections/Controls
2
3
6
4
1
5
1
AC Power Receptacle – Connect the AC power cord here.
Important! Please verify that voltage is correct, for your feeder, before connecting.
2
Interlock Connector – Feeder Interface Cable from tabber connects here.
3
Stand Alone Switch – Allows machine to run when not signaled by host machine.
4
Speed Control Knob – Used to set the speed of the feeder.
Important! The feeder’s transport speed must be set slower than the tabber’s transport
speed, in order to generate at least a 2” gap between pieces.
5
Power Switch – Used to power the feeder on/off.
6
Jog Button. – Runs feeder at preset speed for setup (over-rides interlock controls)
Interlock Control Switch
This switch, located on bottom of feeder, must be set to N.C.
N.C.: Closed Input = Run
N.O.: Closed Input = Stop
NOTE: The power must be cycled (off and on) to
recognize a change in this switch position.
11