Technical specifications – Remotec ZTS-110 V3.14 User Manual
Page 40

40
Q Can I use 2 or more ZTS‐110 in my house? What is the max. units if yes?
A Yes and it is very depends on the capability of gateway / controller. For example, gateway can
supports up to 8, 16 or 32 ZTS‐110 in a network.
Q What is the recommended battery type for ZTS‐110 and what is estimated batteries service life?
A We recommend using alkaline batteries for ZTS‐110.
Batteries service life is very depend on the number of usage per day. Normally, batteries service
life is around 1 year while operated in FLiRS mode.
If you are using battery and somehow it is in Z‐Wave Always Listening Mode, or if you are using
battery as back up, and the AC power is down, the battery will drain very fast, battery will only
survive 3‐5 days.
Technical Specifications
Model no.
BW8031US (ZTS‐110US)
BW8031AU (ZTS‐110AU)
BW8031EU (ZTS‐110EU)
RF frequency
908.4MHz (US) (ZTS‐110US)
921.4MHz (AU) (ZTS‐110AU)
868.4MHz (EU) (ZTS‐110EU)
RF operating distance
up to 100ft outdoor line of sight, in unobstructed environment
Z‐Wave association group
Supports 3 association groups, max. 5 nodes ID can be assigned
to these association groups.
LCD
TN type with white backlight
VA=66.5mmx28.5mm
Powered by
Dry battery AA x 4pcs or
24 VAC +/‐ 20% 50/60Hz
Relay contact
Voltage: 24 VAC 50/60 Hz
Current: 1A Max. (inductive)
Temperature measurable range
32 – 99 °F / 0 – 40 °C
Temperature display resolution
0.5°F / 0.1 °C
Temperature Setting range
41‐99 °F / 5‐37 °C
Temperature
Operating: 32 – 122 °F / 0 – 50 °C
Storage: 23 – 140 °F / ‐5 – 60 °C
Dimension (L x H x T)
145mm x 100mm x 25mm
Weight
170g (Batteries excluded)
Z‐Wave device type
Basic Device Class: Routing_Slave
Generic Device Class: Thermostat
Specific Device Class: Thermostat general v2
Z‐Wave Command Class
Controlled Supported
COMMAND_CLASS_THERMOSTAT_FAN_MODE
NO
YES
COMMAND_CLASS_THERMOSTAT_FAN_STATE
NO
YES
COMMAND_CLASS_THERMOSTAT_MODE
NO
YES
COMMAND_CLASS_THERMOSTAT_SETPOINT
NO
YES
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE
NO
YES
COMMAND_CLASS_THERMOSTAT_SETBACK
NO
YES
COMMAND_CLASS_SENSOR_MULTILEVEL
NO
YES
COMMAND_CLASS_CLOCK
NO
YES